ETS-Lindgren 3301B Active Rod & Field Antenna (Archived) User Manual

Page 24

Advertising
background image

24

| Power

Circuitry

The battery charger is protected against overcurrent by a 200 mA 250 VAC

time-delay fuse. If it becomes necessary to replace the fuse, use a fuse of the

same type and rating to maintain safe operations. The fuse is accessible by

removing the two Phillips head screws on the underside of the unit. The output of

the battery charger is protected against overcurrent conditions by use of

fold-back circuitry.

7.1.2 Specifications

Input voltage:

115/230 VAC selectable

Input frequency:

50/60 Hz

Input power:

20 VA max

Protection class:

Class II double insulated

Input fuse rating:

200 mA time-delay type 5 x 20 mm

Input power connection:

IEC-320 power inlet

Output voltage:

12 VDC (13.5-15 VDC)

Output current:

350 mA

Safety approvals:

TUV, CSA

7.2 Battery Low Indicator

If the Battery Low/Power On indicator on the front of the unit does not illuminate

when the power switch is on, the batteries should be recharged.

7.3 Fuses

Located inside the Model 3301B are two fuses, one for each battery. To replace

the fuses:

Disconnect the power cord and charger before opening the unit.

Replace the fuses with either Type AC size 0.5 AMP fast acting, or

5 x 20 mm fuses.

1. Use a Phillips head screwdriver to carefully remove the screws around

the edge of the bottom panel. Lift the bottom panel off the unit.

Archived 3/18/10

Advertising