Configuration – Kontron VM62 User Manual

Page 39

Advertising
background image

VM62(A) / VM42(A) User’s Manual

Chapter 3 Configuration

3

3. C

ONFIGURATION

The VM62(A) / VM42(A) has twelve jumpers fitted to the board. The list of default jumper settings is shown below.

Table 3.0.0.1: VM62(A) / VM42(A) Default Jumper Settings

Jumper

Default Setting

Description

Wire

J1

Set

SYSCLK connected to VME

J2

Set

On-board RESET generator to VME

J8

Open

Boot from VME disabled

J9

Open

Boot from MP memory interface disabled

Solder

J3
J4
J5

Dependent on board

CPU frequency

J6

Set

Clock connected to 68EN360

J7

Dependent on board

CPU type

J10

Open

Write protection of EEPROM disabled

J11
J12

Dependent on board

SRAM size

J14

Open

Signal GND not connected to Protective GND

J131 - J134

Dependent on board

Processor power supply

Note

Jumpers J1, J2, J8 and J9 are normal wire jumpers that can be configured by the user. The other
jumpers are solder jumpers and are factory set.

May 17, 1996

© 1995 PEP Modular Computers

Page 3-1

Advertising
This manual is related to the following products: