5 vme control/status register, Vme control/status register -13 – Kontron VM162 User Manual

Page 35

Advertising
background image

VM162/VM172

Chapter 2 Functional Description

Juli 23, 1997

Page 2- 13

© PEP Modular Computers

2.5.5 VME Control/Status Register

The VME Control/Status Register is a one byte wide register with read/write access at default address
CD 00 00 05 (HEX).

Note: All bits except bit 4 (First Slot Detection) are cleared after reset. The firmware of the board initia-
lizes some of them at startup according to the default parameters stored in the EEPROM.

Register Description

Note: All bits are cleared during a reset. FSD is set dependent on the slot position of the board in the
system. The board’s firmware initializes EN_DTR, EN_BERR2 and BADR[3-0] during startup follo-
wing default parameters stored in the serial EEPROM.

Name

Value

Reset (HW)
Slot 1

Other

Reset PEP (SW)
Slot 1

Other

Description

P_IRQ5
bit 7

EN_DPR
bit 6

EN_BERR2
bit 5

FSD
bit 4

BADR3 -
BADR0
bits 3-0

1

1

1

1

0

0

0

0

0

0

1

0

0

0

0

0

Value stored in
EEPROM

1

0

1

0

Value stored in
EEPROM

Pending mailbox IRQ

Dual-port RAM (inc. mailbox IRQ) for
VME requester enabled. Base address
fixed using BADRx bits

Enable bus monitor timer, all VME
cycles, timeout after 128

µ

s

VMEbus ‘First Slot Detection’ flag,
system controller

VME address location of dual-ported
RAM. Equivalent to VME address lines
A23-A20, programmable from $0-$F in
1 MByte windows, enabled with
EN_DPR

BADR2

BADR3

BADR1

BADR0

CS7 + $5

0

1

2

3

4

5

6

7

P_IRQ5

FSD

EN_BERR2

EN_DPR

Advertising