3.2

Set Control State (Firmware Hub, Boot Order)

Table 6:

Set Control State

COMMAND

LUN

NetFn

CMD

Set Control State (Firmware Hub, Boot Order)

00h

OEM = 3Eh

20h

REQUEST DATA

Byte

Data Field

1

Control ID:
00h = Firmware hub (SPI boot flash) Selection
9Dh = Boot Order Configuration

2

Control State for SPI boot flash selection:
(These settings are stored in EEPROM and applied (to logic) each time the IPMI controller
detects power-on)

00h = Standard SPI boot flash is selected (default)
01h = Recovery SPI boot flash is selected

Please note that this selection may be forcibly overridden either by the DIP Switch SW3,
switch 2 (refer to the AM4022 User Guide, Table 4-3).
To be able to change the SPI boot flash selection via the Set Control State command, the
recovery SPI boot flash must not be previously selected.
In case of a failed boot process from the standard SPI boot flash, the IPMI controller will
select the recovery SPI boot flash and boot the board again.
In case of a boot failure from the recovery SPI boot flash, the board locks up.
Refer to Chapter 8, uEFI BIOS Failover Control - Automatic SPI Boot Flash Selection, for
further information.

Control State for Boot Order Configuration:
(These settings are stored in EEPROM and applied (to logic) each time the IPMI controller
detects power-on)

00h = No override, boot as usual
01h = Next boot device is: Floppy
02h = Next boot device is: HDD
03h = Next boot device is: CD
04h = Next boot device is: Network
05h = Next boot device is: USB Floppy
06h = Next boot device is: USB HDD
07h = Next boot device is: USB CDROM

RESPONSE DATA

Byte

Data Field

1

Completion Code