3.4

OEM Module Quiescence Feedback

This command is used to control a graceful shutdown of the AM4022 and is a prerequisite for
the hot swap feature. For further information on hot swap, refer to Chapter 10, Hot Swap.

If the software environment does not support ACPI, a self-written shutdown daemon, can be
used to shut down the system in an orderly manner. For this purpose, Kontron’s latest BSP in-
cludes a Graceful Reboot and Shutdown Daemon, “grnsd”.

If ACPI is fully supported, this command can be used to set a timeout time for the case that the
ACPI means (ACPI daemon, etc.) are unable to shut down the system in time. As a default val-
ue at system start this time is set to 0 (endless wait).
Table 8:

OEM Module Quiescence Feedback

COMMAND

LUN

NetFn

CMD

OEM Module Quiescence Feedback

00h

OEM = 3Eh

40h

REQUEST DATA

Byte

Data Field

1

Control bits:
[7] - 1b = set quiesce wait timeout
[6] - 1b = quiescence acknowledge (OS ready)
[5] - 1b = OS daemon present
[4:0] Reserved

2

Quiesce wait timeout [sec]
a) An OS daemon is present (refer to bits above):

This is the maximum time from the moment on that the MMC receives FRU Control
(Quiesce) request until it sends back the appropriate Module Hot Swap event message.

b) No OS daemon is present (refer to bits above):

This is the maximum time from the moment on that the MMC receives FRU Control
(Quiesce) request until it sends back the appropriate Module Hot Swap event message. If
sleep state is recognized before timeout, the Module Hot Swap event message will be sent
immediately. If the time is set to 0 (default after reset,) the Module Hot Swap event
message will only be sent after recognition of sleep state (signal).

RESPONSE DATA

Byte

Data Field

1

Completion code

2

Control bits:
[7] - Reserved
[6] - 1b = quiescence acknowledge (OS ready)
[5] - 1b = OS daemon present
[4] - 1b = quiesce request (FRU Control)
[3] - Reserved
[2] - 1b = graceful reboot request (FRU Control)
[1] - 1b = quiescence reached (MMC acknowledge)
[0] - 1b = module hot swap switch opened

4

Quiesce wait timeout (valid only if OS daemon present = 1)