Figure 2. input power path block diagram – Kontron SMARC Evaluation Carrier User Manual

Page 13

Advertising
background image

User’s Guide

13

www.kontron.com

J29

BENCH
SUPPLY
CONNECTOR

IF CHARGER POWER
AND / OR BATTERY
POWER ARE USED,
THEN BENCH SUPPLY
INPUT MUST BE LEFT
OPEN

3.0V TO 5.25V MODULE POWER

3.0V TO 5.25V CARRIER POWER

J28

CHARGER
CONNECTOR

J23, J24, J25

BATTERY
CONNECTORS

V_CHARGER

BATTERY
SELECT
JUMPERS

V_BAT

IN

IN / OUT

BATTERY CHARGER

CIRCUITS

OUT

STEP-DOWN SWITCHER

WIDE INPUT RANGE

NOT USED FOR SINGLE LEVEL CELLS

IN

OUT

IS USED FOR TWO AND THREE LEVEL

SERIES CELLS

ENABLE

5V OUTPUT IF
SWITCHER IS USED

J56

J55

MODULE POWER

CARRIER POWER

BATTERY

V_CHARGER

V_BAT

V_BAT

CONFIG

NOMINAL RANGE

SINGLE LEVEL

~ 5V

3.6V

3.0V - 4.2V

TWO SERIES

~10V

7.2V

6.0V – 8.4V

THREE SERIES

~15V

10.8V

9.0V – 12.6V

Resistor

P-FET

J27
Switcher Bypass Jumper

3.0V – 5.25V IF
SWITCHER IS
BYPASSED

(SINGLE LEVEL CELL)

JUMPERS J56 AND J55
MUST BE OPEN WHEN
POWER IS BROUGHT IN
FROM BENCH SUPPLY
CONNECTOR J29

Figure 2. Input Power Path Block Diagram

Caution!

There are two different ways to power the SMARC Evaluation Carrier and Module:

»

Bench Power Connector J29 (with jumpers J55 and J56 open).

»

Battery Charger / Battery Power Path - J28, J23, J24, J25 (with jumpers J55 and J56 closed; connector J29

open and not used).

Caution!

These paths are mutually exclusive – you must use one or the other. More details on power options, battery

options, etc. may be found in subsequent sections of this manual.

The Bench Supply connection, through J29, is convenient and easy to use. The two J29 power feeds may be wired

together and can be sourced from a single 5V supply or used separately to allow Module and Carrier power

measurements and voltage range validation.

Caution!

If using the Bench Supply power path, jumpers J55 and J56 must be open.