7.10 Jumpers J50 and J52 – Battery Select – Thermistor Paths

Corresponding to the chosen battery combination, battery pack thermistor selection is done using jumpers J50 and J52

as per the table below:

Function

Inserted

Not inserted

3.6V Li-Ion (1 cell, BAT1)

J50 (Pin 3-4)

All others

3.6V Li-Ion (2 cells, parallel, BAT1 & BAT2)

J50 (Pin 1-2)

J50 (Pin 3-4)

J52 (Pin 3-4)

All others

7.2V Li-Ion (2 cells, series, BAT1 & BAT2)

J50 (Pin 2-3)

J52 (Pin 3-4)

All others

10.8V Li-Ion (3 cells, series BAT1, BAT2, &

BAT3)

J50 (Pin 2-3)

J52 (Pin 2-3)

All others

7.11 Jumpers J55 and J56 – Input Power Path

Jumpers J55 and J56 connect the Evaluation Carrier battery charging subsystem to the rest of the Evaluation Carrier.

Refer to Figure 2 Input Power Path Block Diagram for an illustration. There are two different ways to power the ULP-

COM Evaluation Carrier:

»

Bench Power Connector J29 (with jumpers J55 and J56 open).

»

Battery Charger / Battery Power Path - J28, J23, J24, J25 (with jumpers J55 and J56 closed; connector J29

open and not used).

Caution!

These paths are mutually exclusive – you must use one or the other.

Caution!

The Bench Supply connection, through J29, is convenient and easy to use. The two J29 power feeds may be

wired together and can be sourced from a single 5V supply. If using the Bench Supply power path, jumpers J55 and

J56 must be open.