Kontron SMARC Evaluation Carrier User Manual

Page 60

Advertising
background image

User’s Guide

60

www.kontron.com

Part

Address (7 bit)

Address (8 bit)

I/O (Use as Output)

Default 1 R275

Out

Default 2 R275

In

U35

TI

TCA9554

0x22

0x44 / 0x45

P0

V_5V0_EN

Enabled

CARRIER_PWR_ON

P1

V_3V3_EN

Enabled

CARRIER_PWR_ON

P2

V_1V8_EN

Enabled

CARRIER_PWR_ON

P3

V_1V5_EN

Enabled

CARRIER_PWR_ON

P4

V_5V0_USB_EN

Enabled

CARRIER_PWR_ON

P5

V_3V3_PCIE_EN

Enabled

CARRIER_PWR_ON

P6

CAN0_1V8_EN

Enabled

CARRIER_PWR_ON

P7

CAN1_1V8_EN

Enabled

CARRIER_PWR_ON

Part

Address (7 bit)

Address (8 bit)

I/O (Use as Input)

Notes

U34

TI

TCA9554

0x24

0x48 / 0x49

P0

PG_5V0

Power Good – 5V rail

P1

PG_3V3

Power Good – 3.3V rail

P2

Not used

P3

PG_1V5

Power Good – 1.5V rail

P4

PG_5V0_USB

Power Good – 5V USB rail

P5

PG_3V3_PCIE

Power Good – 3.3V PCIe rail

P6

PG_SWITCHER

Power Good – Bat Step Down

P7

Not used

If resistor R275 is omitted, then the power rails shown above come on whenever the Evaluation Carrier has power. If

R275 is installed with a low value resistor, then the power rails are disabled until the Module asserts the

CARRIER_PWR_ON signal