Installation information, Inspecting and handling the unit, Installation order – Pridiom Floor and Ceiling PFCM183HX Installation Manual User Manual

Page 3: Caution

Advertising
background image

2

installation manual

To install properly, please read this "installation manual" at
first.

The heat pump must be installed by qualified persons.

When installing the indoor unit or its tubing, please follow
this manual as strictly as possible.

If the heat pump is installed on a metal part of the building,
it must be electrically insulated according to the relevant
standards to electrical appliances.

When all the installation work is finished, please turn on
the power only after a thorough check.

Regret for no further announcement if there is any change
of this manual caused by product improvement.

2. INSTALLATION INFORMATION

Ground the heat pump.
Do not connect the ground wire to gas or water pipes,
lightning rod or a telephone ground wire.

Inappropriate

grounding may result in electric shocks.

Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in
electric shocks.

Connect the outdoor unit wires , then connect the indoor
unit wires.

You are not

allowed

to connect the heat pump with the

power

supply until the wiring and piping is done

.

While following the instructions in this installation
manual, install drain piping in order to ensure proper
drainage and insulate piping in order to prevent
condensation.
Improper drain piping may result in water leakage and
property damage.

Install the indoor and outdoor units, power supply wiring
and connecting wires

should be

at least 1 meter away

from televisions or radios in order to prevent image
interference or noise.
Depending on the radio waves, a distance of 1 meter may not
be sufficient enough to eliminate the noise.

The appliance is not intended for use by young children
or infirm persons without supervision.

Don't install the heat pump in the following

circumstance:

There is petrolatum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing

in the air (near a hot spring).

The Volt vibrates violently (in the factories).

In buses or cabinets.

In kitchen where it is full of oil gas.

There is strong electromagnetic wave existing.

There are inflammable materials or gas.

There is acid or alkaline liquid evaporating.

Other special conditions.

If the refrigerant leaks during installation, ventilate the
area immediately.
Toxic gas may be produced if the refrigerant comes into the
place contacting with fire.

The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.

After completing the installation work, check that the
refrigerant does not leak.
Toxic gas may be produced if the refrigerant leaks into the
room and comes into contact with a source of fire, such as a
fan heater, stove or cooker.

INSTALLATION ORDER

Select the location;

Install the indoor unit;

Install the outdoor unit;

Install the connecting pipe ;

Connect the drain pipe;

Wiring;

Test operation.

CAUTION

3. INSPECTING AND HANDLING THE UNIT

At delivery, the package should be checked and any damage should
be reported immediately to the the service agent.

When handling the unit, take into account the following:

Fragile, handle the unit with care.

Keep the unit upright in order to avoid compressor
damage.

Choose on before hand the path along which the unit is to be
brought in.

Move this unit as originally package as possible.

When lifting the unit , always use protectors to prevent belt
damage and pay attention to the position of the unit’s centre of
gravity.

1

2

3

4