2 load cells, 3 enclosure disassembly, 4 replacement parts – Rice Lake 120 Digital Weight Indicator User Manual

Page 10: Load cells, 3 enclosure disassembly 2.4 replacement parts

Advertising
background image

6

120 Installation Manual

2.2.2

Load Cells

Load cell wires can be wired up one of two ways
depending upon which indicator model is purchased.
Refer to the 6-pin connector instructions or the load
cell cord grip plug instructions to connect to the load
cell wires.

6-Pin Connector

The load cell or junction box cable attaches to the
round 6-pin connector, Port 2 (see Figure 2-1 on
page 5
). Table 2-2 shows the pin assignments for

Port 2.

Table 2-2. Load Cell Connector (Port 2) Pin Assignments

Port 2 Pin

Function

1

+SIG

2

+EXC

3

+SENSE *

4

–EXC

5

–SENSE *

6

–SIG

* For 4-wire connections, short pin 2 to pin 3, pin 4 to pin 5.

Load Cell Cord Grip Plug

For models having the load cell cord grip, route cable
through the load cell cord grip and tighten the cord
grip. Next, remove connector J1 from the CPU board
which is located in the lower right side of the CPU
board. The connector plugs into a header on the board.
Wire the load cell cable from the load cell or junction
box to connector J1 as shown in Table 2-3.

Table 2-3. J1 Pin Assignments with Load Cell Cord Grip

J1

Function

1

–EXC

2

–SEN

3

–SIG

4

+SIG

5

+SEN

6

+EXC

2.3

Enclosure Disassembly

CAUTION

Use a wrist strap to ground yourself and
protect components from electrostatic
discharge (ESD) when working inside the
indicator enclosure.

If the indicator enclosure must be opened for
maintenance, do the following:

1. Disconnect power to the unit. Remove tilt stand.

2. Remove two fillister head screws and the setup

switch cover plate from back of enclosure.

3. Loosen self-tapping screw at top center of back

of enclosure.

4. Lift up the forward edge of the rubber feet on

bottom of enclosure for access to two additional
self-tapping screws. Loosen both screws.

5. Press down on top of back half of the enclosure

to release tabs. Open enclosure by separating the
housing at the top of the indicator. (CPU board
is mounted to front half of enclosure; power,
communications, and load cell connections all
connect to the bottom of the CPU board.)

6. Reverse steps to reassemble enclosure.

2.4

Replacement Parts

Table 2-4 lists replacement parts for the 120 indicator.

Table 2-4. Replacement Parts

PN

Description

78609

CPU Board

78610

Switch panel membrane

15799

9-pin socket for D-sub communications cable

15774

Shell for D-sub communications cable

83429

Setup switch cover plate

83430

Fillister head screw

83432

Self-tapping screw (enclosure)

83431

Rubber foot

83428

Tilt stand wing knob

78949

Optional wall-mount tilt stand

78611

9V power supply adapter for 115V units

78612

9V power supply adapter for 230V units

Advertising