0 installation, 1 unpacking and assembly, 2 enclosure and connectors – Rice Lake 120 Digital Weight Indicator User Manual

Page 9: 1 serial communications, Installation, Serial communications

Advertising
background image

Installation

5

2.0

Installation

This section provides information for connecting load cell and serial communications cables to the 120 indicator.

2.1

Unpacking and Assembly

Immediately after unpacking, visually inspect the 120 to ensure all components are included and undamaged.
The shipping carton should contain the indicator with attached tilt stand, this manual, and a parts kit. If any parts
were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately.
The parts kit contains the items listed below:

Capacity and identification labels

Load cell connector (PN 82505)

9V power supply adapter (PN 78611 for 115 VAC units, PN 78612 for 230 VAC units)

2.2

Enclosure and Connectors

The back of the 120 enclosure provides a 3-pin power connection, 9-pin D-sub connector for communications,
and an available 6-pin connector or load cell cord grip connector for load cell connection (see Figure 2-1).

The setup switch, used for placing the indicator into configuration mode, is located in the recess on the underside
of the enclosure. The setup switch is protected by a cover plate and secured with a fillister head screw (not shown
in Figure 2-1).

SETUP

PORT 1

PORT 2

COMMUNICATIONS

LOAD CELL

9VDC ADAPTER

SWITCH

D B - 9
Connecto

r

L o a d C e l l
Connect ion
s h o w n w it h
6 - p i n
C o n n e c t o r
(Port 2)

L o a d C e l l
C o r d G r i p
Available

Communications Port 1

Setup Switch

Figure 2-1. Back View of

120

Enclosure, Showing Load Cell DB-9 Connector, Communications Connectors and Setup

Switch Location

2.2.1

Serial Communications

The serial communications cable attaches to the male
D-Sub connector, Port 1 (see Figure 2-1 on page 5).
Port 1 provides connections for the EDP (Electronic
Data Processing) port and the printer port. Table 2-1.
shows the pin assignments for Port 1.

The EDP port supports RS-232 communications only;
the printer port provides either active 20 mA output or
RS-232 transmission. Both ports are configured using
the SERIAL menu. See Section 3.0 on page 7 for
configuration information.

Table 2-1. Serial Connector (Port 1) Pin Assignments

Port 1

Pin

Port

Function

1

Printer

RS-232 TxD

2

EDP

RS-232 TxD

3

RS-232 RxD

4

not used

5

EDP/Printer

RS-232 Ground / –20 mA OUT

6

N/C

not used

7

8

9

Printer

+20 mA OUT

Advertising