Rice Lake 920i Programmable HMI Indicator/Controller - Profibus DP Interface User Manual

Page 12

Advertising
background image

8

520/720i/820i/920i

Profibus DP Installation and Programming Manual

Tertiary Units

Command: 18, 0x012
Parameter: Scale number

Command 18 switches the current format of the
specified scale to the tertiary units configured for that
scale, if available. This command is valid for the

920i

only.

Units Key Press (toggle units)

Command: 19, 0x013
Parameter: Scale number

Command 19 toggles the current format of the
specified scale to the next units configured for that
scale, as available.

Print Request

Command: 20, 0x014
Parameter: Scale number

Command 20 causes the indicator to execute a print
command for the current scale.

Display Accumulator

Command: 21, 0x015
Parameter: Scale number

Command 21 causes the value of the accumulator for
the specified scale to be displayed and returned. This
command is only valid if the accumulator for the
specified scale is enabled.

Clear Accumulator

Command: 22, 0x016
Parameter: Scale number

Command 22 clears the value of the accumulator for
the specified scale. This command is only valid if the
accumulator for the specified scale is enabled.

Push Weight to Accumulator

Command: 23, 0x017
Parameter: Scale number

Command 23 adds the net weight on the specified
scale to the value of the accumulator for the specified
scale. The scale must return to net zero between
accumulations. The indicator returns the accumulated
weight data for the specified scale. This command is
only valid if the accumulator for the specified scale is
enabled.

Return Gross as Integer

Command: 32, 0x020
Parameter: Scale number

Command 32 returns the gross weight value for the
specified scale as an integer.

Return Net as Integer

Command: 33, 0x021
Parameter: Scale number

Command 33 returns the net weight value for the
specified scale as an integer.

Return Tare as Integer

Command: 34, 0x0022
Parameter: Scale number

Command 34 returns the tare weight value for the
specified scale as an integer.

Return Piece Count

Command: 35, 0x023
Parameter: Scale number

Command 35 returns the piece count value for the
specified scale. This command is valid only for the

520

indicator, and only if count mode is enabled.

Return Current Display as Integer

Command: 37, 0x025
Parameter: Scale number

Command 37 returns the weight value for the
specified scale as currently displayed. This may
include gross, net, tare, piece count, or accumulator
values, as enabled. On the

920i

, the weight value is

returned in the mode used to display a scale widget.

Return Accumulator as Integer

Command: 38, 0x026
Parameter: Scale number

Command 38 returns the accumulator value for the
specified scale. This command is only valid if the
accumulator for the specified scale is enabled.

Return Rate of Change as Integer

Command: 39, 0x027
Parameter: Scale number

Command 39 returns the current rate of change value
for the specified scale. This command is valid only for
the

720i

,

820i

,

920i

.

Return Peak as Integer

Command: 40, 0x028
Parameter: Scale number

Command 40 returns the net peak value for the
specified scale. This command is valid only for the

520

indicator, and only if the peak hold function is

enabled.

Set Batching State

Command: 95, 0x05F
Parameter: State (0 = off; 1 = auto; 2 = manual)

C o m m a n d 9 5 s e t s t h e b a t c h i n g ( B AT C H N G )
parameter. Indicator status is returned with the current
weight for the last scale specified.