GSD File

;=================================================================

; GSD-File for Profibus Indicator Interface

; Rice Lake Weighing Systems

;

; Version V0.4

;

; Date : 9/18/2002

; File : RLWS088B.GSD

;=================================================================

#Profibus_DP

; <Unit-Definition-List>

GSD_Revision

= 1

; This file works with text readers.

Vendor_Name

= "Rice Lake Weighing Systems"; Manufacturer's name

Model_Name

= "Profibus Indicator Interface"; Equipment supported

Revision

= "V1.2"; Version of the GSD file

Ident_Number

= 0x088B; Profibus Device ID

Protocol_Ident= 0

; Profibus DP protocol

Station_Type

= 0

; This is a slave device

FMS_supp

= 0

; No FMS support

Hardware_Release = "Serial REV B / Parallel Rev A"

Software_Release = "Serial v1.00 / Parallel v1.12";

9.6_supp

= 1

; These baud rates are supported

19.2_supp

= 1

45.45_supp

= 1

93.75_supp

= 1

187.5_supp

= 1

500_supp

= 1

1.5M_supp

= 1

3M_supp

= 1

6M_supp

= 1

12M_supp

= 1

MaxTsdr_9.6

= 60

; Time delay needed after a message is sent

MaxTsdr_19.2

= 60

MaxTsdr_45.45

= 250

MaxTsdr_93.75

= 60

MaxTsdr_187.5

= 60

MaxTsdr_500

= 100

MaxTsdr_1.5M

= 150

MaxTsdr_3M

= 250

MaxTsdr_6M

= 450

MaxTsdr_12M

= 800

Redundancy

= 0

; Redundancy not supported

Repeater_Ctrl_Sig = 2

; Repeater control signal TTL

24V_Pins

= 0

; 24 V pins not connected

Implementation_Type= "SPC3"