GSD File

13

; Slave-Specification:

Freeze_Mode_supp= 1

; Freeze mode is supported

Sync_Mode_Supp = 1

; Sync-mode is supported

Auto_Baud_supp = 1

; Auto baud rate detection supported

Set_Slave_Add_Supp= 0

; Set_Slave Add is not supported

Min_Slave_Intervall= 1

; 100us between poll cycles of the slave

Modular_Station= 1

; Modular device (can be set up multiple ways)

Max_Module

= 1

; Maximum number of modules

Max_Input_Len

= 8

; Maximum number of input bytes

Max_Output_Len = 8

; Maximum number of output bytes

Max_Data_Len

= 16 ; Maximum number of bytes transferred

Fail_Safe

= 0

; State CLEAR not accepted

Max_Diag_Data_Len= 6

Modul_Offset

= 1

; First slot number.

Slave_Family

= 3@TdF@OTHER; Function class: I/O

; UserPrmData: Length and Preset:

User_Prm_Data_Len= 0

; <Module-Definition-List>

Module

= "4 WORDS I/O Consistent " 0xD3,0xE3

1

EndModule