0 profibus interface specifications, Profibus interface specifications – Rice Lake 920i Programmable HMI Indicator/Controller - Profibus DP Interface User Manual

Page 18

Advertising
background image

14

520/720i/820i/920i

Profibus DP Installation and Programming Manual

5.0

Profibus Interface Specifications

Power Requirements

Bus Adapter Card with DeviceNet Module, DC Power:

Supply voltage: 6 VDC, supplied by

520

/

820i

/

920i

bus

Typical current draw:

370 mA

Power consumption:

2.22 W

Indicators, Typical AC Load:

520

Power (TRMS):

4.63 W

Current (TRMS):

42.5 mA

720i

Power (TRMS):

3.08 W

Current (TRMS):

41.1 mA

820i

Power (TRMS):

3.08 W

Current (TRMS):

41.1 mA

920i

Power (TRMS):

3.08 W

Current (TRMS):

41.1 mA

Communications Specifications

Profibus-DP Network Communications:

Twisted-pair cabling at: 9.6K, 19.2K, 45.45K, 93.75K,
187.5K, 500K, 1.5M, 3M, 6M or 12Mbps

Update rate is dependent on the configured baud rate and the
number of network nodes. Maximum update rates are:

520

:

up to 120 updates/sec

720i

:

up to 960 updates/sec

820i

:

up to 960 updates/sec

920i

: up to 960 updates/sec

Environmental Specifications

Temperature:

–10° to +40° C (14° to 104° F)