Rice Lake 550 Digital Chair Scale Technical Manual

ATOUT

Algorithm maximal exponent
— Maximum value is 15.
Values above 15, will not let
you proceed and will return to
the previous value.

Value (10)

The display toggles between a numeric value and ATOUT.
If you don’t want to change this value, press the BMI key to
move to the next setting. Example: from ATOUT to TOFF. If
you want to change the value, use the following steps.

1.

Press the ENTER key to change value starting with
the right most digit.

2.

Use the Up/Down arrow keys to increment/
decrement numbers.

3.

Press the BMI key to move to the left.

4.

Use the Up/Down arrow keys to increment/
decrement numbers.

5.

When done, press the ENTER key to move to the
next parameter (TOFF).

TOFF

Auto off timer — Measured in
minutes.
0 = always on.
Maximum is 9 minutes.
When using an external power
supply, this parameter is
irrelevant.

5
4
3
2
1
0
9
8
7
6

The display toggles between a numeric value and TOFF.
If you don’t want to change this value, press the BMI key to
move to the next setting. Example: from TOFF to UNITS.
Press the ENTER key to move to the next parameter. (UNITS).
If you want to change the value, use the following steps.

1.

Press the ENTER key to change values.

2.

Use the Up/Down arrow keys to change the
available parameters.

3.

When done, press the ENTER key to move to the
next parameter (UNITS).

UNITS

Units — Selects the unit of
measure. It can be either

Kg/Lb, Kg only or Lb only.

KG/LB
KG
LB

The display toggles between unit of measurements and UNIT.
If you don’t want to change this value, press the BMI key to
move to the next setting. Example: from UNITS to OP. If you
want to change the value, use the following steps.

1.

Press the ENTER key to change values.

1.

Press the Up/Down arrow keys to change the value.

2.

When done, press the ENTER key to move to the
next parameter (OP).

OP

Binary options:
OP0 — Live weighing options
(0=disable, 1=enable)
OP1 — Communication
protocol (0=ESC,
1=maintenance)
OP2 — BMI menu (0=disable,
1=enable)
OP3 — RTC power
(0=disable, 1=enable)
OP4 - Semi-Auto-Live —
(0=disable, 1=enable)
OP5 - Full calculation —
(0=spatial, 1=multiply by
(0=disable, 1=enable
OP6 - Tare - (0=disable,
1=enable
OP7 - Bat type — (0=dry
batteries, 1=rechargeable
batteries)
OP8 — OIML mode -
(0=disable, 1=enable

OP0
OP1
OP2
OP3

The display toggles between a binary option and POO-0.
If you don’t want to change this value, press the BMI key to
move to the next setting. If you want to change the value, use
the following steps.

1.

Press ENTER to change parameters.

2.

Use the Up/Down arrow keys to select the display
value you want to change.

3.

Press the BMI key to move the flashing cursor.

3a. Use the Up/Down arrows to change the value.
3b. Press the BMI key to move the flashing cursor.

4.

Press the ENTER key to save all of the display
parameters. SAVE appears on the display.

5.

Press the ENTER key again and DONE appears
indicating that you are now done entering all of the
parameters of the scale.

Press the BMI key to cycle back to the top level menu choices, ie: PROG/CALIB/DEF/DONE/TEST