Rice Lake SURVIVOR LV Series Livestock Ring Scale User Manual

Page 38

Advertising
background image

Note

34

590 AG Indicator Operators Manual

When the first group of a load is complete, an arrow annunciator on the right side of the LCD display points to
Group Mode (group) to signify the indicator is in the middle of collecting data from group’s that make up a
load.

Since power standby mode may engage which powers down the indicator, this indicates to the operator that
the indicator is still in the middle of collecting load data when the indicator is powered back on. The previous
group data and accumulating totals are saved in case of power down in the middle of collecting load groups.

3. If a reprint of the last group ticket is required, press the Print key to resend that data to the serial port. A

REPRINT header and trailer will print on ticket.

4. Repeat head count (Section 6.1.3), and shrink factor (Section 6.1.2) if required, as needed for the number

of groups that will be in the load.

5. When all groups for a load are complete, press the Load Total key and the Load Ticket data will be sent to

the serial port. This data includes accumulated totals of head count, total weight, etc. See Figure 6-1.

Group Weight Format
========================
Group Weight - 1
Head Count: 4
Weight: 429.7 lb with 5.00% Shrink
Avg Weight: 107.4 lb
Accumulated Gross Weight: 740.6 lb

Group Weight Reprint Format
===========================
**** REPRINT ****
* *

Group Weight - 1
Head Count: 4
Weight: 429.7 lb with 5.00% Shrink
Avg Weight: 107.4 lb
Accumulated Gross Weight: 740.6 lb
* *
**** REPRINT ****

Total Load Weight Format
===========================
Total Load Weight
Groups: 3

Total Gross Weight: 1408.6 lb

Total Head Count: 12

Total Weight: 1408.6 lb with Shrink
Shrink Percentage: 0.00%

Avg Weight: 117.3 lb

Note

After the load data is sent to the serial port, the totaling accumulators are reset to zero, the Group Mode
(group) annunciator is cleared and the display hold is released if it was indicated.

Figure 6-1. Print Examples

6. Another load can now be started.

There is no reprint ability for the Load Total data.

Note

Pressing the Print key when not in Group Mode (group), will send the current gross weight displayed to the
serial port.