590 AG Indicator Operators Manual

3.2.2

Format Menu

DSPDIV

5D

2D

1D

MULT

0.45359

number

PRIMAR

SECNDR

6SEC

4SEC

3SEC

2500MS

2SEC

1500MS

750MS

500MS

250MS

8SEC

DSPRAT

DSPDIV

1D

5D

2D

DECPNT

888880

888888

88888.8

8888.88

888.888

88.8888

8.88888

DECPNT

888880

888888

88888.8

8888.88

888.888

88.8888

8.88888

UNITS

OZ

KG

LB

T

TN

NONE

G

UNITS

TN

OZ

KG

G

T

LB

NONE

VERS

PROGRM

PFORMT

SERIAL

CALIBR

CONFIG

FORMAT

1SEC

Figure 3-5. Format Menu

FORMAT Menu

Parameter

Choices

Description

Format submenu

PRIMAR

DECPNT
DSPDIV
UNITS

Primary Units – Specifies the decimal position, display divisions, and units used for the
primary units. See below for submenu parameter descriptions.

Primary Units submenus

DECPNT

888888
888880
8.88888
88.8888
888.888
8888.88
88888.8

Decimal point location. Specifies the location of the decimal point or dummy zeroes in the
primary unit display. Value should be consistent with local legal requirements.

DSPDIV

1D
2D
5D

Display divisions. Selects the minimum division size for the primary units displayed weight.

UNITS

lb
kg
OZ
TN
T
G
NONE

Specifies primary units for displayed and printed weight. Values are: lb = pound;

kg = kilogram; OZ = ounce; TN = short ton; T = metric ton; G = gram

Note

Indicators sold outside North America are configured with kg for both
primary and secondary units.