0 sequence of operation, 1 entering presets softkey menu, Sequence of operation – Rice Lake 920i FlexWeigh Systems - 102 User Manual

Page 17

Advertising
background image

Entering Presets Softkey Menu

13

4.0

Sequence of Operation

The following instructions explain a basic sequence of operation for the System 102 Automatic Fill, Automatic
Discharge Filler
.

4.1

Entering Presets Softkey Menu

Note that the front panel E-stop button must be in the stopped position (pushed in) to enable any of the
following keypad entries:

The System 102 has the capability to allow the operator to modify the presets/weights. Use the following
instructions to do this.

Figure 4-1. Presets Menu Screen

1. Press the

Presets

softkey. Softkeys in Figure 4-2 are displayed.

2. The following softkeys are available as shown in Figure 4-2.

Figure 4-2. Presets Softkey Parameters

3. Press the corresponding softkey to edit the data. Parameters that can be edited include:

• Target weight

• Dribble weight

• Preact weight

• Zero tolerance weight

Note

- - - - -

Target

Dribble

Preact

Near Zero

Consec. #

Subtotal

Total

200.0 Lb

75

0.0

10.0

23

1687 Lb

3468 Lb

Presets

Setup
Menu

Totals

4/28/2011

10:20AM

SCALE #1

SCALE
#1

Gross
Lb

- - - - -

Target

Dribble

Preact

Near Zero

Consec. #

Subtotal

Total

200.0 Lb

75

0.0

10.0

23

1687 Lb

3468 Lb

Dribble
Weight

Exit

Target
Weight

Preact
Weight

Zero Tol
Weight

4/28/2011

10:22AM

SCALE #1

SCALE
#1

Gross
Lb