Sequence of Operation
The following instructions explain a basic sequence of operation for the System 102 Automatic Fill, Automatic
Discharge Filler.
4.1
Entering Presets Softkey Menu
Note that the front panel E-stop button must be in the stopped position (pushed in) to enable any of the
following keypad entries:
The System 102 has the capability to allow the operator to modify the presets/weights. Use the following
instructions to do this.
Figure 4-1. Presets Menu Screen
1. Press the
Presets
softkey. Softkeys in Figure 4-2 are displayed.
2. The following softkeys are available as shown in Figure 4-2.
Figure 4-2. Presets Softkey Parameters
3. Press the corresponding softkey to edit the data. Parameters that can be edited include:
• Target weight
• Dribble weight
• Preact weight
• Zero tolerance weight
Note
- - - - -
Target
Dribble
Preact
Near Zero
Consec. #
Subtotal
Total
200.0 Lb
75
0.0
10.0
23
1687 Lb
3468 Lb
Presets
Setup
Menu
Totals
4/28/2011
10:20AM
SCALE #1
SCALE
#1
Gross
Lb
- - - - -
Target
Dribble
Preact
Near Zero
Consec. #
Subtotal
Total
200.0 Lb
75
0.0
10.0
23
1687 Lb
3468 Lb
Dribble
Weight
Exit
Target
Weight
Preact
Weight
Zero Tol
Weight
4/28/2011
10:22AM
SCALE #1
SCALE
#1
Gross
Lb