Configuration

45

REGULAT

NTEP
CANADA
INDUST
NONE
OIML

Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.

• OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater

than zero. NONE allows tares to be acquired at any weight value.

• OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is

at no load. NONE allows tares to be cleared at any weight value.

• NTEP and OIML modes allow a new tare to be acquired even if a tare is already

present. In CANADA mode, the previous tare must be cleared before a new tare can be
acquired.

• NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net

mode as long as the current weight is within the specified ZRANGE. In OIML mode, the
scale must be in gross mode before it can be zeroed; pressing the ZERO key in net
mode clears the tare.

• INDUST provides a set of subparameters to allow customization of tare, clear, and print

functions in non-legal-for-trade scale installations. See Level 4 parameter descriptions
in Table 3-9 on page 47.

The value specified for this parameter affects the function of the front panel TARE and ZERO
keys. See Section 10.2 on page 109 for a complete description of TARE and ZERO key
functions for each of the regulatory modes.

REGWORD

GROSS
BRUTTO

Sets the term displayed when weighing in gross mode. Selecting BRUTTO replaces the
Gross annunciator with Brutto.

CONTACT

Allows specification of contact information for use in

iQUBE

2

alert messages. See Level 3

submenu descriptions in Table 3-8 on page 46.

LOCALE

OFF
ON

Locale. Set this parameter ON to enable the LATUDE and ELEVAT parameters. Specifying
latitude and elevation of the scale site provides compensation for gravitational effects.
Attached scales must be recalibrated after changing this parameter from OFF to ON.

NOTE: Gravitational compensation settings do not affect

iQUBE

2

scales.

LATUDE

45
0–90

Latitude. Specify the latitude of the scale site in degrees. This parameter is shown only if
LOCALE=ON.

ELEVAT

345
±0–9999

Elevation. Specify the elevation of the scale site in meters. Valid values are –9999 through
9999. This parameter is shown only if LOCALE=ON.

IMAGE

NEGATIVE
POSITIVE

Specifies whether the indicator display is presented as blue-on-white or white-on-blue.

The default value, NEGATIVE, shows the standard blue-on-white image when using the
stock LCD display; the optional outdoor display shows white-on-blue. When using the
outdoor display, set this value to POSITIVE to show the standard, blue-on-white display
image, then use the LCD contrast potentiometer to adjust for optimal viewing.

LANGUAGE

ENGLISH
language

Specifies the language and character set used for

920i

prompts and printing.

Level 3 submenus

DATEFMT

MMDDYYYY
DDMMYYYY
YYYYMMDD
YYYYDDMM

Specifies the format used to display or print the date.

DATESEP

SLASH
DASH
SEMI

Specifies the date separator character.

TIMEFMT

12HOUR
24HOUR

Specifies the format used to display or print the time.

TIMESEP

COLON
COMMA

Specifies the time separator character.

FEATURE Menu

Parameter

Choices

Description

Table 3-7. FEATURE Menu Parameters (Continued)