3 rate of change, Rate of change – Rice Lake iRite IDE User Manual

Page 38

Advertising
background image

34

920i

Programming Reference

TareType values returned:

NoTare

There is no tare value associated with the specified scale.

PushbuttonTare

The current tare was acquired by pushbutton.

KeyedTare

The current tare was acquired by key entry or by setting the tare.

SysCode values returned:

SysInvalidScale

The scale specified by

S

does not exist.

T

is unchanged.

SysOK

The function completed successfully.

Example:
TT : TareType;

GetTareType (Scale1, TT);

if TT=KeyedTare then …

SetTare

Sets the tare weight for the specified channel.

Method Signature:
function SetTare (S : Integer; U : Units; W : Real) : SysCode;

Parameters:

[in]

S

Scale number

[in]

U

Units (Primary, Secondary, Tertiary)

[in]

W

Tare weight

SysCode values returned:

SysInvalidScale

The scale specified by

S

does not exist.

SysInvalidUnits

The units specified by

U

is not valid.

SysLFTViolation

The tare operation would violate configured legal-for-trade restrictions for the
specified scale. No tare is acquired.

SysOutOfRange

The tare operation would acquire a tare that may cause a display overload. No tare
is acquired.

SysDeviceError

The scale is reporting an error condition.

SysOK

The function completed successfully.

Example:
DesiredTare : Real;

DesiredTare := 1234.5;

SetTare (Scale1, Primary, DesiredTare);

5.1.3

Rate of Change

GetROC

Sets R to the current rate-of-change value of scale S.

Method Signature:
function GetROC (S : Integer; VAR R : Real) : SysCode;

Parameters:

[in]

S

Scale number

[out]

R

Rate of change value

SysCode values returned:

SysInvalidScale

The scale specified by

S

does not exist.

SysDeviceError

The scale is reporting an error condition.

SysOK

The function completed successfully.

Example:
ROC : Real;

GetROC (Scale3, ROC);

WriteLn (Port1, "Current ROC is", ROC);