GetSPBand

Sets V to the current band value (BANDVAL parameter) of the setpoint SP.

Method Signature:
function GetSPBand (SP : Integer; V : Real) : SysCode;

Parameters:

[in]

S

P

Setpoint number

[out]

V

Band value

SysCode values returned:

SysInvalidSetpoint

The setpoint specified by

SP

does not exist.

SysInvalidRequest

The setpoint specified by

SP

has no hysteresis (BANDVAL) parameter.

SysOK

The function completed successfully.

Example:
SP7Bandval : Real;

GetSPBand (7, SP7BAndval);

WriteLn (Port1, "Current Band Value of SP7 is", SP7Bandval);

GetSPCaptured

Sets V to the weight value that satisfied the setpoint SP.

Method Signature:
function GetSPCaptured (SP : Integer; V : Real) : SysCode;

Parameters:

[in]

S

P

Setpoint number

[out]

V

Captured weight value

SysCode values returned:

SysInvalidSetpoint

The setpoint number specified by

SP

is less than 1 or greater than 100.

SysInvalidRequest

The setpoint has no captured value.

SysOK

The function completed successfully.

GetSPCount

For DINCNT setpoints, sets Count to the value specified for setpoint SP.

Method Signature:
function GetSPCount (SP : Integer; VAR Count : Integer) : SysCode;

Parameters:

[in]

S

P

Setpoint number

[out]

Count

Count value

SysCode values returned:

SysInvalidSetpoint

The setpoint number specified by

SP

is less than 1 or greater than 100.

SysInvalidRequest

The specified setpoint is not a DINCNT setpoint.

SysOK

The function completed successfully.

GetSPDuration

For time of day (TOD) setpoints, sets DT to the current trip duration (DURATION parameter) of the setpoint SP.

Method Signature:
function GetSPDuration (SP : Integer; VAR DT : DateTime) : SysCode;

Parameters:

[in]

S

P

Setpoint number

[out]

DT

Setpoint trip duration

SysCode values returned:

SysInvalidSetpoint

The setpoint specified by

SP

does not exist.

SysInvalidRequest

The setpoint specified by

SP

has no DURATION parameter.

SysOK

The function completed successfully.