Rice Lake iRite IDE User Manual

Page 60

Advertising
background image

56

920i

Programming Reference

Example:
SP2Preval : Real;

GetSPPreact (2, SP2Preval);

WriteLn (Port1, "Current Preact Value of SP2 is", SP2Preval);

GetSPPreCount

Sets Count to the preact learn interval value (PCOUNT parameter) of setpoint SP.

Method Signature:
function GetSPPreCount (SP : Integer; Count : Integer) : SysCode;

Parameters:

[in]

S

P

Setpoint number

[out]

Count

Preact learn interval value

SysCode values returned:

SysInvalidSetpoint

The setpoint specified by

SP

does not exist.

SysInvalidRequest

The setpoint specified by

SP

has no preact learn interval (PCOUNT) parameter.

SysOK

The function completed successfully.

Example:
SP3PCount : Integer;

GetSPPreCount (3, SP3PCount);

WriteLn (Port1, "Current Preact Learn Value of SP3 is", SP3PCount);

GetSPTime

For time of day (TOD) setpoints, sets DT to the current trip time (TIME parameter) of the setpoint SP.

Method Signature:
function GetSPTime (SP : Integer; VAR DT : DateTime) : SysCode;

Parameters:

[in]

S

P

Setpoint number

[out]

DT

Current setpoint trip time

SysCode values returned:

SysInvalidSetpoint

The setpoint specified by

SP

does not exist.

SysInvalidRequest

The setpoint specified by

SP

has no TIME parameter.

SysOK

The function completed successfully.

Example:
SP2TIME : DateTime;

GetSPTime (2, SP2TIME);

WriteLn (Port1, "Current Trip Time of SP2 is", SP2TIME);

GetSPValue

Sets V to the current value (VALUE parameter) of the setpoint SP.

Method Signature:
function GetSPValue (SP : Integer; VAR V : Real) : SysCode;

Parameters:

[in]

S

P

Setpoint number

[out]

V

Setpoint value

SysCode values returned:

SysInvalidSetpoint

The setpoint specified by

SP

does not exist.

SysInvalidRequest

The setpoint specified by

SP

has no VALUE parameter.

SysOK

The function completed successfully.

Advertising