2 connect cable – Rice Lake AX 3040 User Manual

Page 12

Advertising
background image

Junction Box location inside
the box end of the weigh
pad.

8

AX3040 Operator Manual

Figure 3-3. Junction Box Position

3.2

Connect Cable

The Rice Lake AX3040 uses military style connectors between the load cell, the junction box, and on the cable that

connects the two weigh pads. The Rice Lake AX3040 also comes with a 50 foot homerun cable to enable the

installer to hook up the Rice Lake AX3040 to the indicator. Figure 3-4 shows a typical wiring diagram.

Weigh Pad #2

Weigh Pad
Connection Cable

Homerun Cable

Load Cell

Pigtail Cable

Junction Box

Load Cell Cable

Load Cell Cable

Figure 3-4. Cabling to the Indicator

1. Once the weigh pads are put into place, connect them using weigh pad connection cable provided.
2. Connect homerun cable to j-box indicator connection and run the cable out the side of the weigh pad to the

indicator, connect to the indicator per the indicator instruction manual.

3. Ensure all cables are protected from crushing and pinching.

Figure 3-5. Run Homerun Cable Out the Side of the

AX3040

to the Indicator