Installation

3

2.0

Installation

The following section describes information on unpacking, site preparation, assembly and installation of the Rice

Lake AX3040.

2.1

Installation Overview

Standard installation consists of the following steps:

1. Select a site
2. Check for levelness and smoothness of site
3. Unpack weigh pads and ramps
4. Attach ramps to weigh pads
5. Connect cables
6. Calibrate unit

2.2

Site Preparation

Careful consideration must be taken when preparing a site to install the Rice Lake AX3040.

Important

Note

The scale must be placed on a flat and level hard surface. The material should be equal to or better than

3000 psi. concrete.

Never load the weigh pads beyond capacity.

Avoid areas where the weigh pads could receive damaging side impacts or shock damage.

Avoid areas where water may damage pads, which are not meant for washdown environment.

The site should have a level grade for the approach and exit.

If the Rice Lake AX3040 is not on level ground, errors can occur due to weight being transferred toward

and away from the weigh pads (due to unlevel grade). Also friction in the vehicle’s suspension system can

draw the weight off the axle being weighed - especially if the brakes are applied.

Ensure the area is clear of rocks and debris.

All cables must be protected against crushing and/or cutting, or moisture.

2.3

Unpacking the AX3040

Remove all packing material that surrounds the scale and inspect it for visible damage caused during shipment. If

any parts were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately.

Homerun cable, manual,
and 4 lifting eyebolts
taped to weighbridge

Shipping method may
vary, typical is shown.

Note

Figure 2-1. Packaging Kit