0 service information, 1 cleaning and maintenance, 2 maintenance checklist – Rice Lake AX 3040 User Manual

Page 16: Service information

Advertising
background image

12

AX3040 Operator Manual

5.0

Service Information

The following sections provide information to keep the Rice Lake AX3040 running at peak performance.

Note

Disconnect power from the system prior to inspection or cleaning.

5.1

Cleaning and Maintenance

After proper installation, maintenance is the most critical factor in the operation and life expectancy of the Rice

Lake AX3040. Maintenance checks are surprisingly simple, but are often overlooked or ignored until problems

arise.
It is recommended that the owner do inspections on a daily and weekly basis, and mechanical inspections should be

done at least every six months. Actual frequency of these inspections is relative to the environmental conditions

and usage of the AX3040.
A variety of cleaning procedures should be used to maintain the longevity of the AX3040.

Load Cell Trays

Use either air or light water pressure to clean accumulated dirt and debris from the trays. If water is used to clean

the trays, use air pressure to dry them.

Connectors

If the connectors show signs of dirt or corrosion, clean them with a small stiff (dry) brush. Clean connector pins

with a commercial non-residue contact cleaner. Do not use oil or a silicon base cleaner. They will leave a residue

that can trap dirt. Also, denatured alcohol in a trigger spray bottle is an excellent cleaner. Drench the connector

with the cleaner. Wait until the connectors have thoroughly dried before reconnecting.

5.2

Maintenance Checklist

Note

Platforms left assembled for more than one year without maintenance may be difficult to disassemble.

Monitor the system to make sure it functions properly and meets accuracy standards.

Ensure mechanical parts show no damage, deterioration, or change in configuration.

Ensure that all connectors are intact and sealed against moisture and that all are clean and dry.

Ensure that platforms and cables show no sign of salt built up.

Ensure there is no dirt or debris in the load cell trays or under the platforms.

Ensure the pit is clean and drained (where applicable).

Ensure all cables are intact and show no signs of pinching or cuts. Be sure splices are tightly sealed.

Ensure all bolts and nuts tightened to proper torque.

Ensure that operating personnel are familiar with the Rice Lake AX3040 systems safe and proper operation

and maintenance.

Always use a non-corrosive anti-seize compound on all nuts and bolts when re-assembling the platforms.