1 load cell wiring to summing board, 4 replacement load cells – Rice Lake BenchMark LP User Manual

Page 14

Advertising
background image

10

Benchmark Series Low-Profile Bench Scale

4.3.1

Load Cell Wiring to Summing Board

The four load cells are each wired to their respective terminals in the summing board according to the corner

numbering system shown in Figure 4-3 and the coloring code in Table 4-1.

3

4

1

2

Hole for homerun cable

Figure 4-3. Corner numbering (top view)

Table 4-1. Load Cell Wiring

Cable Color Code

Summing Board Terminal

Green

+ Excitation

Black

- Excitation

White

+ Signal

Red

- Signal

4.4

Replacement Load Cells

Table 4-2. Replacement load cells

Capacity of

Scale

Load Mount

Load Cell

100 lbs

96823

100272

250 lbs

96824

104645

500 lbs

96825

100273

1000 lbs

96826

100274

Advertising