1 load cell wiring to summing board, 4 replacement load cells – Rice Lake BenchMark LP User Manual
Page 14
Advertising
10
Benchmark Series Low-Profile Bench Scale
4.3.1
Load Cell Wiring to Summing Board
The four load cells are each wired to their respective terminals in the summing board according to the corner
numbering system shown in Figure 4-3 and the coloring code in Table 4-1.
3
4
1
2
Hole for homerun cable
Figure 4-3. Corner numbering (top view)
Table 4-1. Load Cell Wiring
Cable Color Code
Summing Board Terminal
Green
+ Excitation
Black
- Excitation
White
+ Signal
Red
- Signal
4.4
Replacement Load Cells
Table 4-2. Replacement load cells
Capacity of
Scale
Load Mount
Load Cell
100 lbs
96823
100272
250 lbs
96824
104645
500 lbs
96825
100273
1000 lbs
96826
100274