3 summing board security, 4 electrical interface to indicator – Rice Lake BenchMark LP User Manual

Page 8

Advertising
background image

4

Benchmark Series Low-Profile Bench Scale

2.3

Summing Board Security

After an NTEP inspector has examined the unit, he/she will install security cables on the summing board cover.

These cables prevent the summing board from being tampered with by an unauthorized individual. If these cables

are removed, NTEP Certification will become void.

Figure 2-2. Summing board cover with security cables installed

2.4

Electrical Interface to Indicator

Twenty feet of 6-wire cable to connect the scale to the weight indicator is supplied with each scale. Both ends have

the wires stripped and tinned.

To access the summing board,

1. Remove the stainless steel platform.
2. Remove lid in the center of the platform, revealing the summing board cover plate.
3. Remove security cables (this will void NTEP Certification).
4. Remove screws on the summing board cover plate and remove lid.

Wire Connections

Remove the summing board cover and connect the wires to the INDICATOR terminal (Figure 2-3). To connect the

indicator wires to the appropriate connectors, push in the quick connect lever with a small screwdriver or ballpoint

pen. When holding the lever, insert the appropriate wire into the exposed wire opening.

JP4

JP2

PT4

PT3

JP3

PT1

EXP

PT2

JP1

1

CELL4

1

CELL1

1

CELL3

1

CELL2

IND

-EX

-SI

SHD

+SI

+EX

M

R

N

I

-SI

S2C

I

A

G

+EX

+SI

-SI

SHD

-EX

I

S

G

A

L

T

+SI

M

S

I

N

L

T

R

+EX

-EX

-SI

SHD

+SI

+EX

+SI

-EX

-SI

SHD

-EX

SHD

+SE

-SE

+EX

Figure 2-3. Summing Board Indicator Terminal

Advertising