2.7.2

Digital I/O

The Digital I/O can be configured as either digital inputs or digital outputs as determined by the Digital I/O menu
(see Section 3.6.5 on page 36). The inputs are active (on) with low voltage (0 VDC) and can be driven by TTL or
5V logic without additional hardware. Use the Digital I/O menu (see Section 3.6.5 on page 36) to configure the
digital inputs. LEDs on the CPU board light when digital inputs are active (see Figure 2-4).

Digital outputs are typically used to control relays that drive other equipment. Outputs are designed to sink not
source, switching current. Each output is a CMOS circuit, capable of sinking 24 mA when active. Digital outputs
are wired to switch relays when the digital output is active (low, 0 VDC) with reference to 5 VDC supply. LEDs
on the CPU board light up when the digital outputs are active (see Figure 2-4).

Table 2-4. J3 Pin Assignments (Digital I/O)

2.7.3

Network Connection to Counterpart

Counterpart has an onboard Ethernet connection. It’s wireless connectivity is made possible with the optional
Lantronix WiPort wireless networking device (PN 108671). Refer to the WLAN installation instructions (PN
108680) included with the option card for installing and configuration instructions.

Figure 2-4. LED Light Locations

Note: The Ethernet LED light is on when connected at 100 mb/s and is off when connected at 10 mb/s.

2.8

Enclosure Reassembly

Once the cabling is complete, position the top plate over the enclosure and reinstall the four screws.

Connector

Pin

Signal

J3

1

+5V

2

Ground

3

DIG I/O 1

4

DIG I/0 2

5

DIG I/O 3

6

DIG I/O 4

LED

LED

JP1 JP2

JP3 JP4

JP5 JP6

PC1

WD1

R
U
N

P
G
M

PWR

+5

+3.3v

C3

ON

SW

ISP

RST

Port 3 LED

Port 1 & 2 LED lights

Port 3 LED

E t h e r n e t L E D
Light

Advertising