Load Cell Replacement
7
5.0
Load Cell Replacement
Removing a Load Cell
1. Unplug AC power from the indicator and disconnect the load cell cable from the indicator.
2. Remove the scale top cover.
3. Use a 1/2" wrench to remove the upper load cell screws.
Top Cover
Upper load cell
screws and
washers
Figure 5-1. Remove Scale Top and Upper Load Cell Screws
4. Remove the scale’s spider plate.
5. Remove the upper spacer and set it aside.
6. Loosen the four overload stop screws and turn each screw in one turn to provide ample clearance for the
new load cell.
Spider Plate
Overload
stop screws
Upper spacer
Figure 5-2. Remove Spider Plate and Upper Spacer