3 connecting the load cell cable, 4 grounding the scale base – Rice Lake CW-90X Base User Manual

Page 8

Advertising
background image

4

CW90B/90XB Bench Scale Installation Manual

2.3

Connecting the Load Cell Cable

The CW-90B and CW-90XB come with a standard 10 foot or 34 inch color-coded load cell cable.

See your indicator manual to determine the proper load cell cable input connectors.

Important

Do not cut the load cell cable. The load cell cable is temperature compensated for an exact cable length.

2.4

Grounding the Scale Base

Scale bases can build up static electricity during weighing operations. If powerful enough, this charge can travel
through the load cell cable to the indicator. To prevent this, all bench scales attached to indicators by just a load cell
cable should be adequately grounded to discharge static and transient electrical surges.

A chassis ground screw is located on the bottom of the platform. Item 7 in Figure 6-1 is an 8-32 NCx3/16 screw
used to facilitate grounding. Use a ground wire of at least 18 gauge copper to connect this screw to the same earth
ground as the attached indicator.

Advertising