0 introduction, 1 cw-90b/90xb bench scale specifications, Introduction – Rice Lake CW-90X Base User Manual

Page 5

Advertising
background image

Introduction

1

1.0

Introduction

This manual provides reference information to install and wire the CW-90B/90XB bench scale which is shown in
Figure 1-1.

Figure 1-1. CW-90B/90XB Bench Scale

The CW-90B and CW-90XB are both NTEP-certified and available in a 10" x 10" (254 mm x 254 mm) and

12" x 12" (304 mm x 304 mm) platform with capacities from 5 to 100 lb (2.5 to 50 kg). The light capacity scales
are constructed with 304 stainless steel to withstand many years of rugged use.

The CW-90B comes with an aluminum environmentally sealed load cell.

The CW-90XB comes with a stainless steel and hermetically sealed IP69K load cell.

1.1

CW-90B/90XB Bench Scale Specifications

Table 1-1 lists the CW-90B and CW-90XB model specifications

Table 1-1. 10" x 10" and 12" x 12" CW-90 Models

CW-90B

CW-90XB

Load Cell

Aluminum environmentally sealed

IP69K Stainless steel

Overload Protection

5 point, independently adjusted

Cable Length

34 inch or 10 ft (3 m) - 6 wire shielded

Output Impendance

350

Maximum Overload

180 to 200% depending on capacity

Compensated Temperature Range

14°F to 104°F (-10°C to +40°C)

Dimensions/Capacities

Size

Capacity

Height

10" x 10"/254 mm x 254 mm

5, 10, and 25 lb/2.5, 5, and 12.5 kg

4.25"/108 mm

12" x 12"/304 mm x 304 mm

25, 50, and 100 lb/12.5, 25, and 50 kg 4.25"/108 mm

.

Advertising
This manual is related to the following products: