15 default parameters for pos terminals, Default parameters for pos terminals – Rice Lake Datalogic PowerScan RF 8000 Series Laser Scanner User Manual

Page 177

Advertising
background image

REFERENCES

169

5.15 DEFAULT PARAMETERS FOR POS TERMINALS


The default values of the RS-232 and Data Format parameters for POS terminals are
listed in the following table:

NIXDORF

Mode

A

FUJITSU

ICL

Mode

RS-232 Group

Baud Rate

9600

9600

9600

Parity Odd

None

Even

Data Bits

8

8

8

Stop Bits

1

1

1

Handshaking

Hardware (RTS/CTS)

None

RTS always ON

ACK/NACK Protocol

Disabled

Disabled

Disabled

FIFO Disabled

Enabled

Enabled

Inter-Character Delay

Disabled

Disabled

Disabled

RX Timeout

9.9 sec

2 sec

9.9 sec

Serial Trigger Lock

Disabled

Disabled

Disabled

Data Format Group

Code Identifier

Custom

Custom

Custom

Header

No Header

No Header

No Header

Terminator CR

CR

CR

Field Adjustment

Disabled

Disabled

Disabled

Code Length TX

Not Transmitted

Not Transmitted

Not Transmitted

Character Replacement

Disabled

Disabled

Disabled

Address Stamping

Disabled

Disabled

Disabled

Address Delimiter

Disabled

Disabled

Disabled

Time Stamping

Disabled

Disabled

Disabled

Time Delimiter

Disabled

Disabled

Disabled


The table below lists all the Code Identifiers available for the POS terminals:

CODE NIXDORF

Mode

A

FUJITSU ICL

Mode

UPC-A A0

A

A

UPC-E C0

E

E

EAN-8 B

FF

FF

EAN-13 A

F

F

Code 39

M

None

C [code length]

Codabar N

None

N

[code

length]

Code 128

K

None

L [code length]

Interleaved 2 of 5

I

None

I [code length]

Code 93

L

None

None

Industrial 2 of 5

H

None

H [code length]

UCC/EAN 128

P

None

L [code length]

MSI O

None

None

GS1 DATABAR™

E

None

None

Other None

None

None

Advertising