Rice Lake Datalogic PowerScan RF 8000 Series Laser Scanner User Manual

Page 188

Advertising
background image

POWERSCAN

®

D8330/M8300

180

POWERSCAN

®

D8330/M8300 READER DATA ENTRY

Beeper

¹

LED Good

Read

Spot Meaning

one beep²

ON

ON

Correct read of a code in normal mode

H L long

TX buffer full (when FIFO is enabled) or
TX error between PowerScan

®

M8300

and BC-8000

H long

ON

ON

Successful advanced format
concatenation

H H H

Timeout expired – operation not
completed

H H long

Error in advanced data formatting

OFF

OFF

Ready to read a code


¹ Only the Beeper Intensity command can modify these signals.

² The data entry good read tone is user-configurable with all the Beeper commands

in the Reading Parameters section.

For M-series readers, normally this results in two beeps; the first indicates that the

reader has decoded the code, the second indicates whether BC-80X0 has received
the data. See also par. 5.9.5.


POWERSCAN

®

M8300 POWER

Beeper

LED Meaning

10 short H

10 short blinks Low Battery

H M L

Power off


H = high tone
M = medium tone
L = low tone

POWERSCAN

®

M8300 BIND, JOIN, COPY COMMANDS

Beeper

¹

LED Meaning

Blinking

Command accepted; reader ready to be inserted
into the cradle

L

Success

H L long tones

Failure

Advertising