M8300 SYSTEM AND NETWORK LAYOUTS

23

3.2.3

Master BC-8060 Network Troubleshooting


Two diagnostic strings can be sent via RS-232 from the Host to the Master cradle in
order to have feedback about the network itself.

#+LSlave
Returns a list of all the Slaves recognized at boot up.

Example:
In a network where the Master cradle has address 0188 and one Slave cradle with
address 0001, the response is:

188

1



#+Alive<xxxx>
Executes a continuous Alive request to the slave xxxx in order to monitor the
performance of the connection. A diagnostic message is displayed on the Host.

Example:
If this command is sent for slave cradle with address 0032, the response is:

/*32: BC-80X0 SOFTWARE RELEASE 1.00 20/10/2006*/

if there are no communication errors

/*32: FAIL*/

if there are communication errors.


To exit from this command, reset the system by cycling power to the Master cradle.