HOST CONFIGURATION STRINGS

183

A

HOST CONFIGURATION STRINGS



In this section we provide a description of how to modify the device configuration
using serial strings sent from the Host.

This method requires the RS-232 interface.

The device configuration can be changed by receiving commands from the Host
through the serial interface. When this method is used, the programming sequence
format is the following:

Command

Character sequence in following tables

CR

$-

$+

Carriage return character (0D Hex.)

Enter configuration environment

Exit and Save configuration

Example:

Beeper tone 1

Beeper low intensity

BG1

$-

CR

Carriage return character (0D Hex.)

Exit and save new configuration

AC410132

BH0

Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters

$+

Enter configuration environment

Multiple command programming sequence:


Each configuration parameter setting removes the condition previously active for that
parameter.

NOTE

The device buffer can contain about 400 characters. If your
programming string goes over this value, you must split it into separate
groups and send each group after a delay of at least 3 seconds to give
the reader time to empty the buffer and interpret the commands.