0 indicator setup, 1 serial data inputs, 0 indicator – Rice Lake EL232 XPCD Explosion Proof Remote Serial Display User Manual

Page 16: Setup

Advertising
background image

12

EL232 XCPD Installation Manual

3.0

Indicator Setup

This section is provided to help the installer set up indicators to the EL232 XPCD. You must determine what
indicator will supply the data to the EL232 XPCD. Once this is determined, there are certain setup parameters
which you need to know depending on which indicator is chosen.

The EL232 XPCD supports the following scale formats and are listed in Table 3-1:

UMC Series

General Freedom I and II

Electroscale 560

A & D Instruments 4322, 4323, and 4316

Weightronix WI-110 and WI-120

Toledo indicators with “high speed data format”

Flex-weigh DWM-4

Analogic AN5315, AN5316, AN5322

Masstron M-2500 and M-5000

Fairbanks 90-164 series

Streeter Richardson 9000

Cardinal 738

Instruments with programmable ASCII output

Generic smart receiver mode

3.1

Serial Data Inputs

The EL232 XPCD can accept serial ASCII data sent in RS232C, 20 mA active, or 20 mA passive current loop
formats. These formats determine the electrical way that data is transmitted. The EL232 XPCD can read the data
transmission strings sent by 12 of the more popular scale indicator families as shown in Table 3-1. It cannot read
data from indicators not included in this list unless the formatting exactly matches one on the list (or if you have
a custom program).

Note:

Set up the EL232 XPCD on the bench with the indicator you intend to use before taking it to the installation site.

Brand

Model

Interface

Baud Rate

Data Format/Notes

Condec

1000 - 2000 series

Continuous

1200 or 4800

See Figure 3-1

555/600/700

1200 to 9600

General Freedom

Series I

RS232

1200 to 9600

7 data bits, parity - odd,

Series II

RS232

Electroscale

560

Current loop or RS232 in
continuous mode

1200

See Figure 3-2

A & D Instruments

4322, 4321, 4316

Current loop -passive or
RS232

2400

-

Weightronix

110 and 120

Current loop or RS232

1200 to 9600

-

Toledo

-

Current loop (active or
passive)

4800

-

Flex-Weigh DWM-4

-

Current loop (active or
passive)

1200 to 9600

Data preamble - FF, FF, FF
postamble FF FF 0A

Analogic

AN5315, AN5316,
AN5322

Current loop or RS232 in
continuous mode

1200 to 9600

See Figure 3-3

Table 3-1. Indicator Setup Parameters