Troubleshooting

If any of the following conditions are observed:

Suspect water or leakage in the enclosure

The glass becomes scratched, cracked, chipped, or pitted.

A sealing fitting is sheared off or damaged

The door is hit by a vehicle or object

If you notice or suspect any damage to the unit

Do the following:

Clear area of all personnel and notify plant safety

Shut down all power to the unit at the source and lock out

When the area has been cleared of the hazard and plant safety has declared the area safe for workers to
enter, call your scale dealer

Do not attempt to restart the unit until all damaged parts have been replaced and the unit has been tested.

The most common problems are indicator incompatability, mis-wiring, and mis-programming both in the
indicator and in the EL232 XPCD setup. Double check the output of the meter and make sure something is being
transmitted. Use an oscilloscope, printer, logic probe, or voltmeter to verify that the meter is sending continuous
data. Use a logic probe to check the signal on the EL232 XPCD CPU board to see if data is actually being
received. Connect the probe as shown below.

Figure 5-1. Logic Probe Location

5.2

Recommended Spare Parts

The following table consists of the recommended spare parts for EL232 XPCD, rev. 3.5 board sets.

CL4

CL
4

CL
3

CL
3

CL
2

CL
2

CL
1

CL
1

CL
O

CL
O

RS
2

RS
2

J2

SW2

OPEN

1
2

3
4

RESET

serial data
(TTL levels)

Ground

RLWS Part Number

Description

Quantity

21036

Display board

1

21035

CPU board

1

16347

Serial transmitter chip

2

16348

Serial receiver chip

2

16445

Fuse .5A Slo-blo

1

22134

Display lens

1

Table 5-1. Recommended Spare Parts List

Advertising