Rice Lake IQ Plus 210 Digital Weight Indicator User Manual

Page 20

Advertising
background image

16

IQ plus 2100 Installation Manual

FORMAT Menu

Parameter

Choices

Description

Level 2 submenus

PRIMAR

UNITS
DECPNT
DSPDIV

Specifies the decimal position, display divisions, and units used for the primary units. See
Level 3 submenu parameter descriptions.

ALTUNT

LB
KG
OZ
G
LB/OZ

Specifies which alternate units can be displayed by pressing the UNITS. See Level 3
submenu parameter descriptions.

NOTE: The LB/OZ setting is not a Legal-for-Trade setting.

Level 3 submenus

Primary Units (PRIMAR Parameter)

DECPNT

888.888
8888.88
88888.8
888888
888880
8.88888
88.8888
or
88 88.8
888 88

Decimal point location. Specifies the location of the decimal point or dummy zeroes in the
primary unit display. Value should be consistent with local legal requirements.

If LB/OZ is selected as the primary unit, DECPNT selections are 88 88.8 and 888 88.

DSPDIV

1D
2D
5D

Display divisions. Selects the minimum division size for the primary units displayed weight.

UNITS

LB
KG
OZ
G
LB/OZ

Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; OZ=ounce; G=gram; LB/OZ=pounds and ounces.

Alternate Units (ALTUNT Parameter)

LB
KG
OZ
G
LB/OZ

ON
OFF

Alternate units. Determines which units are displayed when the UNITS button is pressed.
The value for the primary unit (selected on the PRIMAR parameter) is always ON.

NOTE: The LB/OZ setting is not a Legal-for-Trade setting.

Table 3-3. Format Menu Parameters

Advertising