6 default setup – Rice Lake Ishida Astra Operating Manual User Manual
Page 29
ASTRA • Operation Manual • Rev. 0124C
page 23
Chapter 3. Setup Mode
4
➝
➝
ENTER
Example: Date Flag number “3”
➝
Example: Number of days “5”
END
➝
➝
➝
or
➜
Note: Refer to page 14, Section 3.1 to enter the Setup Mode.
PROCEDURES
3
ENTER
➜
ENTER
➜
5
ZERO
MODE
Press the MODE key to return to
Normal Operation mode after all
SETUP mode procedures are
completed.
3.6 Default Setup
1
Press the DOWN ARROW key ( ) until
the Default menu (b04) appears or
key in “4” followed by the DOWN
ARROW key ( ) to enter the menu
directly.
2
Press the ENTER key to enter the Date
Flag menu (b04-01).
Note:
This step sets the default value of the date print
flag.
3
Key in the Date Flag Number (1 to 4)
and press the ENTER key.
1 : Do not print pack date or expire date
2 : Print pack date only
3 : Print expire date only
4 : Print both pack date and expire date
Note:
Number “4” is the default value.
Press the DOWN ARROW key ( ) to
enter the Shelf Life menu.
5
Key in the number of days for expire
date (Max. 3 digits) as the default data
and press the ENTER key.
Note: This step is required only when “3” or “4”
is selected in Step 3 above.
6
Press the END key to return to the
LABEL menu (b01).
4
7