Advertising
background image

6.2 Specifications

page 34

IGX/IGB Series Operation Manual No. 0202A

„

IGB Series

Item Contents

Model Name

IGB-60

IGB-150

<OIML Approved>

Weighing Capacity

60 kg / 150 lb

150 kg / 300 lb

Graduation

0.02 kg / 0.05 lb

0.05 kg / 0.1 lb

Accuracy 1/3000
Weighing Platter

550 mm (L) x 400 mm (W)

Exterior Material

Display: ABS resins
Display pole: Aluminum die-cast
Weighing platter: Stainless (SUS304)

Display Angle Adjust

Angle adjustable from the horizon (0

°) to the front, Knob locking method

Weight

16.0 kg (excluding batteries)

Environmental Condition Temperature from -5°C to +40°C, Relative humidity 80%RH (max.)

without condensation

Power Source

Two dray batteries (not attached to machine), or optional AC adapter
[Battery Life]
Conditions: No option, Temperature 20

°, Relative humidity 60%RH

Two “D” size alkaline batteries (Approx. 500H continuous use)

Power Consumption

2.4 to 6VDC: 25mA

Display

x

LCD

Numerics: 6 digits, Height 25 mm
Mark: Battery. Zero point, Now subtracting tare, Stable, Weight unit

(kg・lb), Over, Under, Accept

Tare Subtraction

x

Key-in tare

x

Preset tare

Preset Function

[Program Mode] 10 PLUs from PLU 1 to PLU 10

(Tare weight, Upper limit, Lower limit)

Upper Limit Range

More than the lower limit, within 5 digits (99999)

Lower Limit Range

Less than the upper limit (5 digits in case of the upper limit = 0)

Auto Power Off

[Setup Mode] None/10min./ 20min./ 30min./ 40min./ 50min./ 60min.

Auto Preset Call-up

[Setup Mode] Function “Yes”/”No” selection

(PLU 1 is called up when the power is ON.)

Battery Check Mode

Yes

Buzzer No
ON/OFF Switch

Option

AC adapter (Dealer option)