Railboss Railroad Track Scale

3.0

Junction Box Installation

The RailBoss Railroad Track Scale TuffSeal

®

junction box (PN 119987) has been designed to connect and trim

four load cells per board. One junction box is required per RailBoss section (i.e., one for double-draft systems,
two for full-draft systems).

WARNING

Electrostatic Charging Hazard
To prevent Electrostatic charging hazard, the equipment shall only be cleaned with a damp cloth.
Sparks can ignite flammable liquid vapors and powders.

3.1

Junction Box Wiring

JP4

PT4

PT3

JP3

JP2

PT1

1

EXP

PT2

JP1

1

CELL4

1

CELL1

1

CELL3

1

CELL2

1

IND

-EX

-SI

SHD

+SI

+EX

M

-SI

S2C

+SI

+EX

-EX

-SI

SHD

+SI

+EX

-EX

-SI

SHD

+SI

+EX

+SI

-SI

-EX

SHD

-EX

SHD

+EX

+SE

-SE

1

EXP

1

IND

-SI

+SI

-EX

SHD

+EX

+SE

-SE

Figure 3-1. Expansion Port Wiring Location

Table 3-1. RailBoss Wiring Assignments

Color

Function

Red

+EXCITATION

Black

–EXCITATION

Green

+SIGNAL

White

–SIGNAL

1. After determining the wiring pattern (see

Figure 3-1 and Table 3-1), route the load cell
cables through the cord grip assemblies and
leave the grips loose until final closure.

2. Before connecting load cell wires to the

terminals, strip the wire insulation back 1/4"
to expose the wire. The spring -loa ded
terminals will accommodate 12-28 gauge
wire.

3. To connect the load cell wires to the

a p p r o p r i a t e c o n n e c t o r s , p u s h i n t h e
quick-connect lever with a small screwdriver.
While holding the lever, insert the appropriate
wire into the exposed wire opening. Release
the screwdriver to allow the spring-loaded
gate to close and lock the wire in place.

Serial Port Assignments

A single or dual A/D card can be used with the scale
depending on if it is a full draft or double draft.

Dual A/D card

Full Draft

Single A/D card

Double Draft

Table 3-2 shows the port numbers assigned for each
slot.

Table 3-2. Serial Port Assignments

Slot Number

Serial Port Assignment

1

1 - Printer (for railcar ticket -
defaults to 9600, None, 8 bits,
parity 1)

2 - iRev