Maintenance 13

2. Remove the plastic plugs.
3. Remove the load cell retainer.
4. Pull load cell away from the lower load cell pin and pull load cell stand cover and load cell assembly up

and out of the load cell stand.

5. Remove the upper load cell pin to release the load cell from the load cell stand cover.
6. Reassemble with new load cell by reversing the steps above.

Plastic Plugs

Load Cell Retainer

Load Cell Assembly

Load Cell Stand Cover

Upper Load Cell Pin

Overload Bolt

Figure 4-2. Load Cell Disassembly and Greasing

Important

Load cell stand cover must fit squarely into the load cell stand before removing the overload bolt
assemblies. See Section 2.2.1
.