Maintenance 13
2. Remove the plastic plugs.
3. Remove the load cell retainer.
4. Pull load cell away from the lower load cell pin and pull load cell stand cover and load cell assembly up
and out of the load cell stand.
5. Remove the upper load cell pin to release the load cell from the load cell stand cover.
6. Reassemble with new load cell by reversing the steps above.
Plastic Plugs
Load Cell Retainer
Load Cell Assembly
Load Cell Stand Cover
Upper Load Cell Pin
Overload Bolt
Figure 4-2. Load Cell Disassembly and Greasing
Important
Load cell stand cover must fit squarely into the load cell stand before removing the overload bolt
assemblies. See Section 2.2.1.