Rice Lake Stationary Livestock Scale - MAS-LC - Operators Manual User Manual

Page 18

Advertising
background image

Load Cell #1

Load Cell #2

Load Cell #4

Load Cell #3

Scale Cable

Junction Box

Trimmers

Load Cell #4

Load Cell #1Load Cell #2

Load Cell #3

Indicator

Black

Green

White

Shield

Red

+E

-E

+S

-S

GND

V1

V2

V3

V4

Load cell wiring shown is effective for all models
later then 09/17/2013, models built prior that date
s h o u l d r e w i r e t h e s c a l e t o t h e u p d a t e d
configuration. For instructions for rewiring,
d o w n l o a d a d d e n d u m x x x x x x f r o m
www.ricelake.com.

Note

14 Rice Lake Stationary Livestock Scale Operator’s Manual

Figure 4-3. Load Cell Wiring Diagram

D

A

B

Indicator

A

D

C

B

Scale

A -EXC Black
B +SIG Green
C +EXC Red
D -SIG White

Connector

C

Figure 4-4. Scale/Indicator System Connection

Advertising