2 j-box connections, J-box 2 detail, 8atv portable truck scale assembly instructions – Rice Lake SURVIVOR ATV User Manual

Page 12: Cable to j-box 2, Load cell cable to connector, Cable from j-box 1, Cable to indicator

Advertising
background image

8

ATV Portable Truck Scale Assembly Instructions

3.2

J-Box Connections

Each J-box contains a JB8SPT summing board with DC transient protection devices. A desiccant such as the
RLWS Industrial Corrosion Inhibitor (PN 16037) should be added to the J-box before final closure.

Each self-contained module has a single J-box located in the J-box pocket. A summing card mounted within the
J-box is used to make all cable terminal connections. All terminal pins are clearly marked as to function.

Load Cell
Cable to
Connector

Load Cell 1 Conduit

Module A

Module B

Load Cell 1, 2
and 3 Conduit

1

4

2

3

SI - Green

SI - White

EX - Red

EX - Black

SHD - Shield

+

-

+

-

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

J3

J4

J7

J8

J6

J5

J2

J1

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

Load Cell #1

Load Cell #3

Load Cell #8

Load Cell #6

Load Cell #2

Load Cell #4

Load Cell #7

Load Cell #5

+SI
-SI

+EX

-EX

SHD

-SEN

+SEN

SHD - Shield

+SI
-SI

+EX

-EX

SHD

-SEN

+SEN

Indicator/J10

Expansion/J9

Cable to J-Box 2

SI - Green

+

SI - White

-

EX - Red

+

EX - Black

-

SEN - Yellow

-

SEN - Blue

+

Load Cell
Cable to
Connector

SI - Green

SI - White

EX - Red

EX - Black

SHD - Shield

+

-

+

-

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

J3

J4

J7

J8

J6

J5

J2

J1

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

Load Cell #1

Load Cell #2

Load Cell #9

Load Cell #3

Load Cell #10

Load Cell #8

+SI
-SI

+EX

-EX

SHD

-SEN

+SEN

SHD - Shield

+SI
-SI

+EX

-EX

SHD

-SEN

+SEN

Indicator/J10

Expansion/J9

Cable from J-Box 1

SI - Green

+

SI - White

-

EX - Red

+

EX - Black

-

SEN - Yellow

-

SEN - Blue

+

SHD - Shield

Cable to Indicator

SI - Green

+

SI - White

-

EX - Red

+

EX - Black

-

SEN - Yellow

-

SEN - Blue

+

J-Box 2 Detail

1

4

2

3

Load Cell 1 and 2 Conduit

Load Cell
4 Conduit

Load Cell Cables
to J-Box

Load Cell 1 Conduit

Module A

Load Cell 1, 2
and 3 Conduit

Load Cell 1 and 2 Conduit

Load Cell
4 Conduit

Load Cell Cables
to J-Box

J-Box 2

J-Box 1

J-Box 1 Detail

Figure 3-2. J-Box Wiring and Conduit

Advertising