2 setting units, 3 setting system id number – Rice Lake TradeRoute HL Series - M2000 Scale User Manual

Page 31

Advertising
background image

27

9. End of procedure.

Note: The toggle switch must be in the NORMAL position for

the normal functions of the system to operate.

6.2 Setting Units

Note: To change units, the Weights and Measures seal will have to be

broken. Contact Rice Lake Weighing Systems prior to breaking the seal or
have a qualified scale dealer break the seal. Breaking the seal may violate the

Weights and Measures approval of the scale.

NOTE: If you attempt to change the units through the indicator, the Weigh
Center will automatically switch the units back to the DIP switch setting (see

below).

1. Open the faceplate where the indicator is mounted. To open the faceplate,
remove the two screws at the top of the panel and fold it forward.

2. Inside the control panel there is a circuit board with a small bank of
switches (DIP switches). These DIP switches are located on the front corner
of the circuit board. As shown in the diagram below, the side of the DIP

switch that is down determines if the switch is in the open or closed position.

3. The units can be in kilograms (kgs) or pounds (lbs). To change this setting

find switch #7 and set appropriately.

Closed = kgs

Open = lbs

6.3 SETTING SYSTEM ID NUMBER

Supply 14 Volts potential to the circuit board through the Truck Cable. Power

up the M2000.

Open DIP-switch 3 on the circuit board.

Key in 20 <SELECT> and enter in the last three digits of the indicator serial

number, e.g. S/N S0750 key in 750, and press <SELECT>.

Close DIP-switch 3.

Advertising