28
6.4 Standard DIP Switch Settings
The standard DIP switch settings on the main circuit board should be set as
follows:
Mobile Multiple Animal
Switch #
Position
Description
1
Open
DO NOT CHANGE
2
Closed
DO NOT CHANGE
3
Closed
DO NOT CHANGE
4
Open
DO NOT CHANGE
5
Open
DO NOT CHANGE
6
Closed
DO NOT CHANGE
7
a) Closed
b) Open
a) Kilograms (kgs)
b) Pounds (lbs)
8
Closed
DO NOT CHANGE
On-Board
The standard DIPswitch settings on the main circuit board should be set as
follows:
Switch #
Position
Description
1
Open
DO NOT CHANGE
2
Closed
DO NOT CHANGE
3
Closed
System ID number
4
Open
DO NOT CHANGE
5
Open
DO NOT CHANGE
6
Closed
DO NOT CHANGE
7
c) Closed
d) Open
c) Kilograms (KGS)
d) Pounds (LBS)
8
Closed
DO NOT CHANGE