Activity log printer, Ring-master – Ring Communications DNA100 User Manual

Page 26

Advertising
background image

April 2012 Digital Network Adapter DNA100

ACTIVITY LOG PRINTER

A serial RS232C printer can be attached to a DNA100 to provide a complete activity log of system. All stations to
be logged must have the printer defined in their SAR. The DNA100 must be configured to drive a printer by
setting SW3-7 off and SW3-8 on. The printer must have a RS232C serial interface. The standard print format is
80 columns, 66 lines per page.

Figure C16 shows a sample printed page of the Crisis Alert Activity Log Printer.

Description of Status Headings :

DATE

The D

ATE

this page was printed. If the date changes before the page is full a new page is printed

with events for the new date.

TIME

The actual time the event on each line occurred.

PRI

P

RIORITY

of the incoming event.

STATUS

Status of each event (C

ALL

, F

AULT

, C

ONNECT

, P

ARK

, C

ANCEL

, R

ESET

, A

LARM

).

EXT

The dial number of the station generating the event.

LOCATION DESCRIPTION

Written description of the location or device stated under the EXT heading.

CONNECTED TO

Indicates the station connected to the device generating the event.

Description of Status :

CALL

C

ALL

to annunciator. This only indicates a call condition was placed from type 1 sub station or

type 3 sub-master station.

CONNECT

Indicates an event being handled in accordance with the annunciator display through Crisis

Alert. (See H

ANDLING

A

N

E

VENT

earlier in this Chapter or in Chapter D - DAD104)

FAULT Indicates a hardware problem for the location printed and sent to the annunciator five seconds after the
fault occurs. The time delay is due to a noise filter in the DXC901 that only records solid faults.

PARK

An event that was placed in P

ARK

. A new C

ONNECT

message will be generated when this event is

retrieved again.

CANCEL

Indicates a disconnection of two devices that were previously connected. For example, a

master station that presses the ‘X’ key on the terminal keyboard using a DNA100 will generate a C

ANCEL

event.

ALARM A

LARM

to annunciator. This indicates that an alarm condition was placed from a type 3 sub-master

station.
PWRFAIL

The CB901 has detected loss of Power. It is now running on battery backup.

ACKNOWL

An event has been acknowledged by a DAD104 (such as PWRFAIL).

CLEAR The Power has been restored to normal for the CB901 central exchange.

22

Ring-Master

Advertising