April 2012 Digital Network Adapter DNA100

INSTALLATION

Each DNA100 in a system can be individually powered from a fuse in the CB901 or a local power supply
operating off 24V regulated DC.

J1 - 8 pin (RJ45) Network connections :

Two modular jacks are provided at the rear of the DNA100. See Figure C1. Use modular cables with straight
through pin configuration only!
An 8-pin (RJ45) modular jack (KB171) and cord (BF640A) are required for
connection to the network.

PIN# - DESIGNATION
1 - No connection.
2 - +12 VDC power input
3 - Data + (positive)
4 - No connection.
5 - No connection.
6 - Data - (negative)
7 - -12 VDC power input
8 - External Alarm.

The maximum total network length is 7000 feet. A unshielded twisted pair cable should be used for the data pair
(24 or 22 AWG).

2

123456

12345678

J3

J2

J1

RS422

RS232

RS485