Ring Communications DNA200 User Manual

Page 6

Advertising
background image

DNA200 OPERATIONS MANUAL

6

2008/05/01

J2 - 9 pin (DB9) RS232 signals :

The DNA200 has a RS232 serial port interface, J2, that can connect to a terminal, printer, or video switcher. Check
your terminal, printer or video switcher manual for the correct RS232 connector type, input, output and handshaking
signal connections.

The maximum length for a RS232 cable connecting the DNA200 and other equipment is 50 feet.

A null-modem (LapLink) cable can be used to connect a DNA200 and a PC computer together if they are close
enough to each other.

If you are going to make your own cable the following is a description of the pinout of the DB9 connector on the
DNA200.

J2

SIGNAL

DIRECTION/

PIN#

NAME

DESIGNATION

1

DCD

Data Carrier Detect, input.

2

RXD

Receive Data, input.

3

TXD

Transmit Data, output.

4

DTR

Data Terminal Ready, output.

5

GND

Signal Ground.

6

DSR

Not used.

7

RTS

Request to Send, output.

8

CTS

Clear to Send, input.

9

RI

Not used.

J3 - 6 pin (RJ11) RS422 signals :